  acdc specification 40100 watts ? compact size ? it & medical approvals ? convectioncooled ? class i and ii construction ? dc input version available (dcm series) ? poe isolation version available (poe series) ? 3 year warranty ECM series input input voltage ? 90-264 vac (120-370 vdc) input frequency ? 47-63 hz; 440 hz* input current ? 40 w: 0.4 a max at 230 vac 60 w: 0.6 a max at 230 vac 100 w: 0.9 a max at 230 vac i nrush current ? 40 a max at 230 vac earth leakage current ? <125 a at 115 vac/60 hz <210 a at 230 vac/50 hz power factor ? en61000-3-2 input protection ? internal t3.15 a, 250 v fuse in line and neutral output output voltage ? see tables output voltage trim ? 5% on 3.3 v & 5 v versions, 10% on other single output models and v1 of multi-output models. (see note 1 for ECM40/60 models) initial set accuracy ? 1.0% v1, 5% v2, v3 & v4 minimum load ? see tables start up delay ? 1.5 s max start up rise time ? 10 ms max hold up time ? 16/75 ms min at 115/230 vac line regulation ? 0.5% load regulation ? 1% single output models; 3% v1, 5% v2 & v3 ECM40/60 multi-output models. 1% v1 & v2, 5% v3 & v4 ECM100 cross regulation ? 2% on ECM40/60 only over/undershoot ? none at turn on/off transient response ? 4% max. deviation, recovery to within 1% in 500 s for a 25% load change ripple & noise ? 1% pk-pk, 20 mhz bandwidth overvoltage protection ? 115-135% vnom, recycle input to reset overload protection ? 110-150% on primary power limit, auto recovery short circuit protection ? trip and restart (hiccup mode) temperature ? 0.05%/c coefficient peak load ? 120% for 100 ms ECM40/60 (see note 3) * safety approvals cover frequency range 47-63 hz xppower.com general efficiency ? 80-85% depending on model isolation ? 4000 vac input to output 2 x mopp ECM100 single output models, 1 x mopp ECM100 multi output and all ECM40/60 models (contact sales for 2 x mopp), 1500 vac input to ground 1 x mopp, 500 vac output to ground switching frequency ? 70 khz typical power density ? 40 w: 4.2 w/in 3 60 w: 6.3 w/in 3 100 w: 7.4 w/in 3 mtbf ? 600 khrs to mil-hdbk-217f at 25 c, gb environmental operating temperature ? 0 c to +70 c. refer to derating curves for specific operating limitations. cooling ? convection & fan-cooled ratings (see derating curves) operating humidity ? 95% rh, non-condensing storage temperature ? -40 c to +85 c operating altitude ? 3000 m shock ? 30 g pk, half sine, 6 axes vibration ? 2 g rms, 5 hz to 500 hz, 3 axes emc & safety emissions ? en60601-1-2, en61204-3, fcc 20780, en55022 & en55011, level b conducted en55022 level a radiated harmonic currents ? en61000-3-2, class a voltage flicker ? en61000-3-3 esd immunity ? en61000-4-2, level 3 perf criteria a radiated immunity ? en61000-4-3, 10 v/m perf criteria a eft/burst ? en61000-4-4, level 3 perf criteria a surge ? en61000-4-5, level 3 perf criteria a, semi f47 conducted immunity ? en61000-4-6, 10 v perf criteria a dips & interruptions ? en61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, perf criteria a, b, b en60601-1, 30% 500 ms, 60% 100 ms, 100% 10 ms, 100% 5000 ms, perf criteria a, a (with 50% load), a, b safety approvals ? en60601-1, ansi/aami es60601-1, csa22.2 no.60601-1 per cul, including risk management, en60950-1, ul60950-1
acdc ECM40 output connector j2 pin single multi 1 v1 +v1 2 v1 +v1 3 rtn rtn 4 rtn rtn 5 nc v3 6 nc +v2 notes 1. v2 will track a change in v1 by the same percentage change in voltage as v1 is trimmed. 2. to receive unit with cover fitted, add suffix -c to model number. for class i operation only. 3. a 120% peak load can be taken for up to 100 ms with a 25% duty cycle. average load not to exceed 40 w. mechanical details notes 1. all dimensions in inches (mm). tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) 2. weight: approx. 0.33 lbs (150 g) 3. cable harnessess with 300 mm wire available. for single output models, order part number ECM40/60s loom ?. for multi-output models, order part number ECM40/60dt loom ?^. 4. mating connector kit available. order part number ECM40/60 conkit ?. 5. covers available. order part number ECM40/60 cover ?^. cover dimensions are 4.49 x 2.52 x 1.52 (114 x 64 x 38.5) 6. 3d drawing files available from www.xppower.com/cad.php. 4 x ?0.156 (3.96) mounting holes ?0.312 (7.92) clearance top and bottom 0.25 x 0.32 faston ground tab 1.20 (30.5) 0.14 (3.5) smd component height 4.00 (101.6) 2.00 (50.8) 1.75 (44.45) 3.75 (95.25) v adj. 6 1 j2 input connector j1 pin 1 line pin 2 neutral j1 mates with molex housing 43061-0003 & molex series 5194 crimp terminals ground tab (0.25 faston) standard j2 mates with molex housing 43061-0006 & molex series 5194 crimp terminals derating curves all ECM40 models convectioncooled all ECM40 models with 5 cfm 20 10 30 40 50 60 70 80 0 % 50% 100% output power ambient temp (c) 0 75% 25% 20 10 30 40 50 60 70 80 0 % 50% 100% output power ambient temp (c) 0 75% 25% note: derate by 10% if cover is fitted consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications. models and ratings output power output 1 output 2 output 3 model number (2) voltage current min/max (3) voltage current min/max voltage current min/max 40 w 5.0 v 0.0 a/8.0 a ECM40us05 7.0 v 0.0 a/5.7 a ECM40us07 9.0 v 0.0 a/4.4 a ECM40us09 12.0 v 0.0 a/3.5 a ECM40us12 15.0 v 0.0 a/2.7 a ECM40us15 18.0 v 0.0 a/2.2 a ECM40us18 24.0 v 0.0 a/1.7 a ECM40us24 33.0 v 0.0 a/1.2 a ECM40us33 48.0 v 0.0 a/0.9 a ECM40us48 +5.0 v 0.5 a/6.0 a +12.0 v 0.1 a/2.0 a ECM40ud21 +5.0 v 0.5 a/6.0 a +15.0 v 0.1 a/1.5 a ECM40ud22 +5.0 v 0.5 a/6.0 a +12.0 v 0.1 a/2.0 a -12.0 v 0.0 a/0.5 a ECM40ut31 +5.0 v 0.5 a/6.0 a +24.0 v 0.1 a/1.0 a -12.0 v 0.0 a/0.5 a ECM40ut32 +5.0 v 0.5 a/6.0 a +15.0 v 0.1 a/1.5 a -15.0 v 0.0 a/0.5 a ECM40ut33 +3.3 v 0.5 a/6.0 a +5.0 v 0.1 a/1.5 a +12.0 v 0.0 a/0.5 a ECM40ut34 +5.0 v 0.5 a/6.0 a +3.3 v 0.1 a/1.5 a +12.0 v 0.0 a/0.5 a ECM40ut35
acdc ECM60 models and ratings 20 10 30 40 50 60 70 80 0 % 75% output power ambient temp (c) 0 100% 25% 50% 2010 30 40 50 60 70 80 0 % 50% 100% output power ambient temp (c) 0 75% 25% note: derate by 10% if cover is fitted output connector j2 pin single multi 1 v1 +v1 2 v1 +v1 3 rtn rtn 4 rtn rtn 5 nc v3 6 nc +v2 1. v2 will track a change in v1 by the same percentage change in voltage as v1 is trimmed. 2. to receive unit with cover fitted, add suffix -c to model number. for class i operation only. 3. a 120% peak load can be taken for up to 100 ms with a 25% duty cycle. average load not to exceed 60 w. 1. all dimensions in inches (mm). tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) 2. weight: 0.33 lbs (150 g) approx. 3. cable harnesses with 300 mm wire available. for single output models, order part number ECM40/60s loom ?. for multi-output models, order part number ECM40/60dt loom ?. 4. mating connector kit available. order part number ECM40/60 conkit ?. 5. covers available. order part number ECM40/60 cover ^? . cover dimensions are 4.49 x 2.52 x 1.52 (114 x 64 x 38.5). 6. selected single output models available in a 3 x 5 footprint for oem quantities. contact sales for details. 7. 3d drawing files available from www.xppower.com/cad.php. 4 x ?0.156 (3.96) mounting holes ?0.312 (7.92) clearance top and bottom 0.25 x 0.32 faston ground tab 1.20 (30.5) 0.14 (3.5) smd component height 4.00 (101.6) 2.00 (50.8) 1.75 (44.45) 3.75 (95.25) v adj. 6 1 j2 input connector j1 pin 1 line pin 2 neutral j1 mates with molex housing 43061-0003 & molex series 5194 crimp terminals. ground (0.25 faston) tab standard. j2 mates with molex housing 43061-0006 & molex series 5194 crimp terminals. derating curves notes consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications. output power output 1 output 2 output 3 model number (2) voltage current min/max (3) voltage current min/max voltage current min/max 60 w 5.0 v 0.0 a/12.00 a ECM60us05 7.0 v 0.0 a/8.60 a ECM60us07 9.0 v 0.0 a/6.70 a ECM60us09 12.0 v 0.0 a/5.00 a ECM60us12 15.0 v 0.0 a/4.00 a ECM60us15 18.0 v 0.0 a/3.30 a ECM60us18 20.0 v 0.0 a/3.00 a ECM60us20 24.0 v 0.0 a/2.50 a ECM60us24 28.0 v 0.0 a/2.14 a ECM60us28 33.0 v 0.0 a/1.80 a ECM60us33 48.0 v 0.0 a/1.25 a ECM60us48 +5.0 v 0.5 a/8.00 a +12.0 v 0.1 a/3.0 a ECM60ud21 +5.0 v 0.5 a/8.00 a +15.0 v 0.1 a/2.5 a ECM60ud22 +5.0 v 0.5 a/8.00 a +12.0 v 0.1 a/3.0 a -12.0 v 0.0 a/0.5 a ECM60ut31 +5.0 v 0.5 a/8.00 a +24.0 v 0.1 a/1.5 a -12.0 v 0.0 a/0.5 a ECM60ut32 +5.0 v 0.5 a/8.00 a +15.0 v 0.1 a/2.5 a -15.0 v 0.0 a/0.5 a ECM60ut33 +3.3 v 0.5 a/8.00 a +5.0 v 0.1 a/1.5 a +12.0 v 0.0 a/0.5 a ECM60ut34 +5.0 v 0.5 a/8.00 a +3.3 v 0.1 a/1.5 a +12.0 v 0.0 a/0.5 a ECM60ut35 mechanical details notes all ECM60 models convectioncooled all ECM60 models with 5 cfm
output voltage output current model number (1) minimum maximum with 5 cfm cooling 3.3 v 0.0 a 15.0 a 20.0 a ECM100us03 5.0 v 0.0 a 15.0 a 20.0 a ECM100us05 7.0 v 0.0 a 11.4 a 14.3 a ECM100us07 9.0 v 0.0 a 8.8 a 11.1 a ECM100us09 12.0 v 0.0 a 7.5 a 8.3 a ECM100us12 15.0 v 0.0 a 6.0 a 6.6 a ECM100us15 18.0 v 0.0 a 5.0 a 5.5 a ECM100us18 24.0 v 0.0 a 4.1 a 4.1 a ECM100us24 28.0 v 0.0 a 3.6 a 3.6 a ECM100us28 33.0 v 0.0 a 3.0 a 3.0 a ECM100us33 48.0 v 0.0 a 2.1 a 2.1 a ECM100us48 acdc 4x ?0.16 (4.0) mounting holes ?0.31 (7.9) clearance top and bottom 0.25 faston ground tab 0.20 (5.1) 2.10 (53.3) 1.20 (30.5) 2.50 (63.5) 2.25 (57.1) 1.25 (3.2) 0.20 (5.1) 1.27 (32.2) 4.50 (114.3) 4.25 (107.9) 0.12 (3.2) j2 1 12 j1 1 2 v adj. 0.14 (3.5) smd component height cover dimensions are 4.98 x 3.01 x 1.54 (126.5 x 76.4 x 39.0) ECM100 models and ratings output connector j2 pin single multi 1 v1 +v1 2 v1 +v1 3 v1 +v1 4 v1 +v1 5 v1 rtn rtn 6 v1 rtn rtn 7 v1 rtn rtn 8 v1 rtn rtn 9 not used +v2 10 not used +v2 11 not used v3 12 not used -v4 mechanical details notes 1. all dimensions in inches (mm). tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) 2. weight: 0.4 lbs (180 g) approx. 3. cable harnessess with 300 mm wire available. for single output models, order part number ECM100s loom ? . for multi-outputs (dual and triple output only), p/n ECM100dt loom ?. 4. mating connector kit available for single output models. order part number ECM100s conkit ?^. 5. covers available. order part number ECM100 cover ?^. 6. available in a 3 x 5 footprint for oem quantities. contact sales for details. 7. 3d drawing files available from www.xppower.com/cad.php. input connector j1 pin 1 line pin 2 neutral j1 mates with molex housing 43061-0003 and molex series 5194 crimp terminals. ground (0.25 faston) tab standard. j2 mates with molex housing 43061-0012 and molex series 5194 crimp terminals. derating curves 2010 30 40 50 60 70 80 0 60 100 output power (w) ambient temp (c) 0 80 20 40 a d c a b c d b us24-48 us12-18 us05 us03 2010 30 40 50 60 70 80 0% 50% 100% output power ambient temp (c) 0 75% 25% note: 1. derate by 10% if cover is fitted. 2. for multi output convection- cooled operation above +50 c derate linearly to 50% at +70 c. notes multi output models single output models 1. to receive unit with cover fitted, add suffix -c to model number. for class i operation only. 2. output 3 available with opposite polarity for oem quantities. consult longform datasheet for installation information regarding optimum thermal ratings in convection-cooled applications. output power output 1 output 2 output 3 output 4 model number (1) convection cooled forced air 5 cfm voltage current min/max voltage current min/max voltage current min/max voltage current min/max 80 w 100 w +5.0 v 0.0 a/12.0 a +12.0 v 0.0 a/3.0 a ECM100ud21 80 w 100 w +5.0 v 0.0 a/12.0 a +15.0 v 0.0 a/3.0 a ECM100ud22 75 w 100 w +5.0 v 0.5 a/10.0 a +12.0 v 0.0 a/3.0 a -12.0 v 0.0 a/0.8 a ECM100ut31 80 w 100 w +5.0 v 0.5 a/10.0 a +24.0 v 0.0 a/2.0 a -12.0 v 0.0 a/0.8 a ECM100ut32 80 w 100 w +5.0 v 0.5 a/10.0 a +15.0 v 0.0 a/3.0 a -15.0 v 0.0 a/0.8 a ECM100ut33 65 w 100 w +3.3 v 0.5 a/10.0 a +5.0 v 0.0 a/5.0 a +12.0 v 0.0 a/0.8 a ECM100ut34 70 w 100 w +5.0 v 0.5 a/10.0 a +3.3 v 0.0 a/5.0 a +12.0 v 0.0 a/0.8 a ECM100ut35 80 w 100 w +5.0 v 0.5 a/10.0 a +12.0 v 0.0 a/3.0 a -5.0 v 0.0 a/0.8 a ECM100ut36 70 w 100 w +5.0 v 0.5 a/10.0 a +15.0 v 0.0 a/3.0 a -5.0 v 0.0 a/0.8 a ECM100ut37 65 w 100 w +5.0 v 0.5 a/10.0 a +3.3 v 0.1 a/5.0 a +12.0 v 0.0 a/0.8 a -12.0 v 0.0 a/0.5 a ECM100uq41 60 w 100 w +3.3 v 0.5 a/10.0 a +5.0 v 0.1 a/5.0 a +12.0 v 0.0 a/0.8 a -12.0 v 0.0 a/0.5 a ECM100uq42 80 w 100 w +5.0 v 0.5 a/10.0 a +24.0 v 0.1 a/2.0 a +12.0 v 0.0 a/0.8 a -12.0 v 0.0 a/0.5 a ECM100uq43 80 w 100 w +5.0 v 0.5 a/10.0 a +24.0 v 0.1 a/2.0 a +15.0 v 0.0 a/0.8 a -15.0 v 0.0 a/0.5 a ECM100uq44 80 w 100 w +5.0 v 0.5 a/10.0 a +12.0 v 0.1 a/3.0 a -12.0 v 0.0 a/0.8 a -5.0 v 0.0 a/0.5 a ECM100uq45 80 w 100 w +5.0 v 0.5 a/10.0 a +15.0 v 0.1 a/3.0 a -15.0 v 0.0 a/0.8 a -5.0 v 0.0 a/0.5 a ECM100uq46 all ECM100 single output models convectioncooled all ECM100 models with 5 cfm
notes 1. can be configured as -48 vdc input. 2. input reverse voltage protection is continuous with automatic recovery. 3. input transients compliant with etsi en300 132:2003. 4. for a fitted cover version, add suffix -c to model number (power derates by 20% with cover fitted) 5. for full product details contact sales, or visit www.xppower.com 6. 5% minimum load required to meet all specification parameters input voltage range (1) input current uvlo output voltage output current model number min (6) max convection -cooling max - 5cfm forced -cooling 36-76 vdc (48 vdc nominal) 1.5 a (2.5 a max) 32 - 35 vdc 12 v 0.25 a 5.00 a 5.00 a dcm6048s12 2.2 a (3.5 a max) 12 v 0.40 a 7.50 a 8.30 a dcm10048s12 dcm60/100 models and ratings output connector j2 pin single 1 12v 2 12v 3 rtn 4 rtn 5 nc 6 nc mechanical details notes 1. all dimensions in inches (mm). tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) 2. weight: dcm60: 0.3 lbs (136 g) approx. dcm100: 0.4 lbs (181 g) approx. 3. cover kits available separately, order part number no. ECM40/60 cover (4.49 x 2.52 x 1.52 (114 x 64 x 38.5)) for dcm60 or part no. ECM100 cover (4.96 x 3.05 x 1.52 (126 x 77.5 x 38.5)) for dcm100. output power derates by 20% with cover fitted. - + 6 j2 1 1 2 j1 2.00 (50.8) 1.75 (44.4) 3.75 (95.2) 4.00 (101.6) 0.125 (3.2) 0.12 (3.2) 0.20 (5.1) 0.87 (22.2) 1.61 (41.0) 0.21 (5.4) smd component height ground connection through mounting holes voltage adjust 4 x 0.15 (3.9) mounting holes ?0.31 (7.9) clearance top and bottom 0.14 (3.5) 1.20 (30.5) + - 12 j2 1 1 2 j1 2.50 (63.5) 2.25 (57.1) 4.25 (107.9) 4.50 (114.3) 0.12 (3.2) 0.12 (3.2) 2.10 (53.3) 0.20 (5.1) 0.20 (5.1) 1.29 (32.8) 1.20 (30.5) smd component height 0.14 (3.5) ground connection through mounting holes voltage adjust 4 x 0.15 (3.9) mounting holes ?0.31 (7.9) clearance top and bottom input connector j1 pin 1 -vin pin 2 +vin j1 mates with molex housing 43061-0003 & molex series 5194 crimp terminals j2 mates with molex housing 43061-0006 & molex series 5194 crimp terminals output connector j2 pin single 1 12v 2 12v 3 12v 4 12v 5 rtn 6 rtn 7 rtn 8 rtn 9 nc 10 nc 11 nc 12 nc input connector j1 pin 1 -vin pin 2 +vin j1 mates with molex housing 43061-0003 & molex series 5194 crimp terminals dcm60 dcm100 j2 mates with molex housing 43061-0012 & molex series 5194 crimp terminals acdc
27-sept-12 input voltage range input frequency input current earth (1) leakage current output power output voltage output current model number 115 vac 230 vac 90-264 vac (120-370 vdc) 47-63 hz 1.8 a max 1.1 a max <1 ma 100 w +56 v 1.8 a poe100us56 poe100 models and ratings notes 1. earth leakage current rated at 264 vac/60 hz. 2. input is protected with internal t3.15 a, 250 v, fuse in line 3. output to ground isolation 1500 vac poe version. 4. for full product details contact sales, or visit www.xppower.com output connector j2 pin 1 56v pin 2 56v pin 3 rtn pin 4 rtn mechanical details notes 1. all dimensions in inches (mm). tolerance .xx = 0.02 (0.50); .xxx = 0.01 (0.25) 2. weight 0.35 lb (158 g) approx. smd component height 4.00 (101.6) 3.75 (95.3) 0.13 (3.2) 1.26 (32.0) 0.20 (5.1) 0.13 (3.2) 2.00 (50.8) 1.75 (44.5) 0.94 (23.8) 0.21 (5.3) 4x ?0.156 (3.96) mounting holes ?0.312 (7.92) clearance top and bottom 0.25 faston ground tab voltage adjust 0.19 (4.8) 1.25 (31.8) j1 j2 l n 1 2 1 input connector j1 pin 1 line pin 2 neutral 0.25 faston earth j1 mates with molex housing 09-50-1031 & molex series 5194 crimp terminals j2 mates with molex housing 09-50-1041 & molex series 5194 crimp terminals derating curves 2010 30 40 50 60 70 80 0 40 80 output power (w) ambient temp (c) 0 60 20 2010 30 40 50 60 70 80 ambient temp () 0 output power (w) 0 40 80 100 60 20 convectioncooled fancooled with 10 cfm acdc